ProLiant DL 380 Maintenance and Service Guide
Diagnostics and Troubleshooting 3-53
Table 3-18
ASR-2 Features
Features Definition
Software error recovery If enabled, ASR-2 is activated if the OS hangs or has a crash that
results in a lockup.
Software error recovery timeout Determines how long the server waits to enable ASR-2 after an OS
lockup.
Standby recovery server option If enabled, ASR-2 activation initiates a switch to a standby recovery
server.
Standby recovery server port Port used to communicate with the recovery server.
Standby recovery timeout Determines how long the server waits to initiate switch after ASR-2
activation.
Software error recovery start option Allows the server to restart either into the OS or into Compaq
Utilities.
Thermal shutdown If enabled, shuts down the server if a critical thermal error occurs.
UPS shutdown If enabled, allows the server to perform a shutdown if a UPS is
activated.
UPS shutdown threshold Determines how long the server waits to shut down after the UPS
is activated. If desired, this number should provide enough time for
an administrator to perform any necessary operations or to
gracefully shut down the server.