HP ProLiant DL380 G6 Server Maintenance and Service Guide

Specifications 94
Maximum peak power
800 W at 100V AC input
900 W at 120V AC input
1200 W at 200V to 240V AC
input
HP ProLiant 750 W Power Supply
Specification Value
Input requirements
Rated input voltage
100 to 120 VAC, 200 to
240 VAC
Rated input frequency
50 Hz to 60 Hz
Rated input current
8.9 A at 100 VAC
4.3 A at 200 VAC
Rated input power
857 W at 100V AC input
824 W at 200V AC input
BTUs per hour
2925 at 100V AC input
2812 at 200V AC input
Power supply output
Rated steady-state power
750 W at 100V to 120V AC input
750 W at 200V to 240V AC input
Maximum peak power
750 W at 100V to 120V AC input
750 W at 200V to 240V AC input
HP ProLiant 460 W Power Supply
Specification Value
Input requirements
Rated input voltage
100 to 120 VAC, 200 to
240 VAC
Rated input frequency
50 Hz to 60 Hz
Rated input current
5.5 A at 100 VAC
2.6 A at 200 VAC
Rated input power
526 W at 100V AC input
505 W at 200V AC input
BTUs per hour
1794 at 100V AC input
1725 at 200V AC input
Power supply output
Rated steady-state power
460 W at 100V to 120V AC input
460 W at 200V to 240V AC input
Maximum peak power
460 W at 100V to 120V AC input
460 W at 200V to 240V AC input
Hot-plug power supply calculations
For hot-plug power supply specifications and calculators to determine electrical and heat loading for the
server, refer to the HP Enterprise Configurator website (http://h30099.www3.hp.com/configurator/).