HP ProLiant DL380 G6 Server Maintenance and Service Guide

Specifications 93
Specifications
Environmental specifications
Specification Value
Temperature range*
Operating
10
°
C to 35
°
C (50
°
F to 95
°
F)
Shipping
-30°C to 50°C (-22°F to 122°F)
Storage
-30°C to 60°C (-22°F to 140°F)
Maximum wet bulb
temperature
28°C (82.4°F)
Relative humidity
(noncondensing)**
Operating
10% to 90%
Non-operating
5% to 95%
* All temperature ratings shown are for sea level. An altitude derating of 1°C per 300 m (1.8°F per 1,000 ft) to 3048
m (10,000 ft) is applicable. No direct sunlight allowed.
** Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude maximum for
storage corresponds to a pressure minimum of 70 KPa.
Power supply specifications
Depending on installed options, the server is configured with one of the following power supplies:
HP ProLiant 1200 W Power Supply
Specification Value
Input requirements
Rated input voltage
100 to 120 VAC, 200 to
240 VAC
Rated input frequency
50 Hz to 60 Hz
Rated input current
10 A at 100 VAC
4.9 A at 200 VAC
Rated input power
930 W at 100V AC input
1348 W at 200V AC input
BTUs per hour
3530 at 120V AC input
4600 at 200V to 240V AC input
Power supply output
Rated steady-state power
800 W at 100V AC input
900 W at 120V AC input
1200 W at 200V to 240V AC
input