HP ProLiant DL380 G5 Data Protection Storage Server Administration Guide (434184-001, September 2006)

Arr ays
See Figure 17. With an array controller installed in the system, the capacity of several physical drives
(P1–P3) can be logically combined into one or mo re logical units (L1) called arrays. When this is
done, the read/write heads of all the c onstituent physical drives are active simultaneously, dramatically
reducing the ov
erall time required for data transfer.
NOTE:
Depending on the storage server model, array conguration may not be possible or necessary.
P1 P3P2
L1
gl0042
Figure 17 Conguri ng arrays from physical drives
Because the read/write heads are simultaneously active, the same amount of data is written to each
drive during any given time interval. Each unit of data is termed a block. The blocks form a set of data
stripes over all the ha rd drives in an array, as shown in Figure 18.
S1
S2
S3
S4
B1
B4
B7
B2
B5
B8
B11B10 B12
B6
B3
B9
gl0043
Figure 18 RAID 0 (data striping) (S1-S4) of data blocks (B1-B12)
For data in the array to be readable, the data block sequence within each stripe must be the same.
This sequencing process is performed by the array controller, which sends the d ata blocks to the drive
write heads in the correct order.
A natural consequence of the striping process is that each hard drive in a given array contains the
same number of data blocks.
NOTE:
If one hard drive has a larger capacity than other hard drives in the same array , the extra capacity is
wastedbecauseitcannotbeusedbythearray.
Fault tolerance
Drive failure, although rare, is potentially catastrophic. For example, using simple striping as shown in
Figure 18, failure of any hard drive leads to failure of all logical drives in the same array, and hence to
data loss.
To protect against data loss from hard drive failure, storage servers should b e con gured with fault
tolerance. HP recommends adhering to RAID 5 congurations.
HP ProLiant DL380 G5 Data Protection Storage Server 39