Compaq ProLiant DL380 Generation 2 Setup and Installation Guide
3-32 Compaq ProLiant DL380 Generation 2 Server Setup and Installation Guide
Compaq Confidential – Need to Know Required
Writer: Rob Weaver Project: Compaq ProLiant DL380 Generation 2 Server Setup and Installation Guide Comments:
Part Number: 203844-001 File Name: d-ch3 Installing Hardware Options.doc Last Saved On: 4/5/01 1:55 PM
Use Figure 3-28 and Table 3-4 to identify the hot-plug fans.
1
2
3
4
5
6
7
8
Figure 3-28. Identifying hot-plug fans (fans shaded for zone identification)
Table 3-4
Hot-Plug Fan Locations
Item Description Configuration
Fan 1 in CPU zone Primary
Fan 2 in CPU zone Redundant
Fan 3 in I/O zone Redundant
Fan 4 in I/O zone Primary
Fan 5 in CPU zone Primary
Fan 6 in CPU zone Primary
Fan 7 in power supply zone Primary
Fan 8 in power supply zone Redundant
To install a redundant hot-plug fan:
1. Remove the access panel. See the “Removing the Access Panel” section
in this chapter.
CAUTION: Do not operate the server for extended periods without the access
panel. Operating the server without the access panel results in improper airflow
and improper cooling that can lead to thermal damage.