Compaq ProLiant DL380 Generation 2 Setup and Installation Guide
Server Specifications F-3
Compaq Confidential – Need to Know Required
Writer: Rob Weaver Project: Compaq ProLiant DL380 Generation 2 Server Setup and Installation Guide Comments:
Part Number: 203844-001 File Name: o-appf Server Specifications.doc Last Saved On: 3/27/01 10:26 AM
Rack Model with Optional Redundant Power Supply
Table F-2
Operating and Performance Specifications
for Rack Model with Redundant Power Supply
Dimensions
Height (without feet) 8.59 cm 3.38 in
Depth 65.45 cm 25.75 in
Width 44.45 cm 17.50 in
Weight (maximum) 27.22 kg 60 lb
Weight (no drives installed) 20.41 kg 47.18 lb
Input requirements
Rated input voltage 100 VAC to 240 VAC —
Rated input frequency 50 Hz to 60 Hz —
Rated input current 6 A (110 V) to 3 A (220 V) —
Rated input power 600 W —
Power supply output
Rated steady-state power 400 W —
Maximum peak power 400 W —
Temperature range
Operating (See note) 10°C to 35°C50°F to 95°F
Shipping (See note) -40°C to 70°C-40°F to 158°F
Relative humidity (noncondensing)
Operating (See note) 10% to 90% —
Non-operating (See note) 5% to 95% —
Maximum wet bulb temperature 28°C 82.4°F
Note: Operating temperature has an altitude derating of 1°C per 1,000 ft. No direct
sunlight allowed. Storage maximum humidity of 95% is based on a maximum temperature
of 45°C. Altitude minimum for storage is 70 KPa.