Compaq ProLiant DL380 Generation 2 Setup and Installation Guide
LED Indicators and Switches E-15
Compaq Confidential – Need to Know Required
Writer: Rob Weaver Project: Compaq ProLiant DL380 Generation 2 Server Setup and Installation Guide Comments:
Part Number: 203844-001 File Name: n-appe LED Indicators and Switches.doc Last Saved On: 4/5/01 2:11 PM
Table E-7
System LEDs and Internal Health LED Status Combinations
System LED and Color Internal Health
LED Color
Status
Red
■ Processor in socket X has failed.
■ Processor X has failed over to offline spare.
■ Processor X is not installed in the socket.
■ Processor X is unsupported.
■ ROM detects a failed processor during POST.
Processor failure, socket X
(Amber)
Amber Processor in the socket is in a pre-failure condition.
Processor failure, both
sockets (Amber)
Red Processors are mismatched (speed and/or type).
PPM failure, slot X (Amber) Red
■ PPM in slot X has failed.
■ PPM is not installed in slot X.
■ PPM is not installed in slot X, but the
corresponding processor is installed.
Red
■ DIMM in slot X has failed.
■ DIMM in slot X is an unsupported type, and no
valid memory exists in another bank.
■ DIMM in slot X has experienced a multi-bit error.
DIMM failure, slot X
(Amber)
Amber
■ DIMM in slot X has reached single-bit
correctable error threshold.
■ DIMM in slot X is in a pre-failure condition.
■ DIMM in slot X is an unsupported type, but valid
memory exists in another bank.
continued