Compaq ProLiant DL380 Generation 2 Setup and Installation Guide

E-4 Compaq ProLiant DL380 Generation 2 Server Setup and Installation Guide
Compaq Confidential Need to Know Required
Writer: Rob Weaver Project: Compaq ProLiant DL380 Generation 2 Server Setup and Installation Guide Comments:
Part Number: 203844-001 File Name: n-appe LED Indicators and Switches.doc Last Saved On: 4/5/01 2:11 PM
Table E-2
Hot-Plug SCSI Hard Drive LED Status Combinations
Activity Online Fault
Means
On Off Off
Do not remove the drive. Removing a drive
during this process causes data loss.
The drive is being accessed and is not configured
as part of an array.
On Flashing Off
Do not remove the drive. Removing a drive
during this process causes data loss.
The drive is rebuilding or undergoing capacity
expansion.
Flashing Flashing Flashing
Do not remove the drive. Removing a drive
during this process causes data loss.
The drive is part of an array being selected by the
Array Configuration Utility.
-Or-
The Options ROMPaq is upgrading the drive.
Off Off Off OK to replace the drive online if a predictive
failure alert is received (see the following section
for details) and the drive is attached to an array
controller.
The drive is not configured as part of an array.
-Or-
If this drive is part of an array, then a powered-on
controller is not accessing the drive.
-Or-
The drive is configured as an online spare.
Off Off On OK to replace the drive online.
The drive has failed and has been placed off-line.