HP Insight Management WBEM Providers for HP integrated VMWare ESXi

System
Temperature Sensor
Table 12-7 HP_AlertIndication_: Temperature Sensor Threshold Exceeded
Property name Property implementation
AlertingManagedElement WBEM path of the SMX_NumericSensor instance
representing the temperature sensor detecting the
exceeded threshold
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 1
EventTime Time of the event or time of the indication if event time
unknown
ProviderName System Temperature
RecommendedActions Ensure that the system is adequately ventilated. Check
for proper room temperature and internal/external
airflow. Add or repair fans and air baffling if
necessary.
SystemName HP_ComputerSystem.Name
SystemCreationClassName HP_ComputerSystem.CreationClassName
HP_AlertIndication
Summary Temperature threshold exceeded detected
EventCategory 23 (System Cooling)
ProbableCause 51 (Temperature Unacceptable)
ProbableCauseDescription Temperature Threshold Exceeded Detected
ProviderVersion 2.2.0.0
NetworkAddresses Contains a list of all the IP addresses (IPv4 and IPv6) of
the computer system generating the indication
OSType SMX_OperatingSystem.) OSType
OSVersion Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>
SystemFirmwareVersion Firmware version of the computer system generating
the indication
SystemSerialNumber Serial number of the computer system generating the
indication
SystemProductID Product ID of the computer system generating the
indication
SystemModel Model name of the computer system generating the
indication
SystemGUID Platform GUID of the computer system generating the
indication