HP Insight Management WBEM Providers for HP integrated VMWare ESXi

System Power
Supply
10-3-10 SMX_PowerSupplyElementLocation
SMX_ElementLocation is used to represent an association between CIM_Location and
CIM_ManagedElement.
Table 10-11
Class: SMX_PowerSupplyElementLocation
Property name Property implementation
Element References CIM_ManagedElement
PhysicalLocation References CIM_Location
10-3-11 SMX_PowerSupplyModule
SMX_PowerSupply is used to model physical power supplies on Servers. Please note: power supply
numbers for existing instances do not change when other power supplies are added and removed.
Table 10-12
Class: SMX_PowerSupplyModule
Property name Property implementation
CIM_ManagedElement
Caption Short description of this power supply from the name
displayed by the MP or iLO and its location. For
example, Power Supply 1 at PowerSupplySlot=2
Power supply 1a at PowerSupplySlot=2
Description Descripton of ths power supply module including
ElementName type and status.
For example: elementname provides power for
powersupplytype. statusdescription.
where elementname represents the value of
ElementName,
powersupplytype represents the corresponding string
value of the PowerSupplyType enumeration and
statusdescription represents the value of
StatusDescriptions[0]
ElementName Short description of this power supply from the name
displayed by the MP or iLO and its location. For
example, Power Supply 1 at PowerSupplySlot=2
Power supply 1a at PowerSupplySlot=2
CIM_ManagedSystemElement
OperationalStatus[0] 2 (OK) – if power supply is operating properly
3 (Dedgraded) – if power supply is degraded
6 (Error) – if power supply has failed