HP Insight Management WBEM Providers for HP integrated VMWare ESXi

Smart Array View
Class
Table 5-1 Class: HPVC_SAController
Property name Property implementation
CIM_ComputerSystem
VMware_Controller
HPVC_SAController
5-2-2 HPVC_SAControllerFirmware
HPVC_SAControllerFirmware represents Smart Array controller firmware. There is one instance per
HBA.
Table 5-2
Class: HPVC_SAControllerFirmware
Property name Property implementation
CIM_ManagedElement
ElementName Smart Array Controller X
Note: VMware Virtual Infrastructure client requires
controller name string X matches “vmwControllerX”
reported in HPVC_SAControllerÆName.
For example, Smart Array Controller HPSA1
CIM_ManagedSystemElement
Name Smart Array Controller X Firmware
CIM_LogicalElement
Caption Smart Array Controller X Firmware
CIM_SoftwareIdentity
InstanceID HPQ:Smart Array Controller X
Manufacturer HP
VersionString Smart Array controller firmware version
For example, 4.12
HPVC_SAControllerFirmware
5-2-3 HPVC_SABattery
HPVC_SABattery represents Smart Array controller battery.
Table 5-3
Class: HPVC_SABattery
Property name Property implementation
CIM_ManagedElement
ElementName Battery on HPSA X
CIM_ManagedSystemElement