HP Insight Management WBEM Providers for HP integrated VMWare ESXi

Smart Array
4-4-15 HP_DeviceIndication: Controller Cache status—
Permanently Disabled
Table 4-109 HP_DeviceIndication: Controller Cache status—Permanently Disabled
Property name Property implementation
HP_DeviceIndication
DeviceModel Array Controller Model string
4-4-16 HP_DeviceIndication: Enclosure Power Supply
status changed to Non Redundant
Table 4-110 HP_DeviceIndication: Enclosure Power Supply status changed to Non Redundant
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PerceivedSeverity 3 (Warning)
IndicationTime Time of indication
CIM_AlertIndication
Description Storage Enclosure Power Subsystem status has
changed to a Non Redundant Status
AlertingMangedElement WBEM path of the SMX_SAStorageEnclosureProcessor
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 301
EventTime Time of the event or time of the indication if event time
unknown
ProviderName HP SmartArray
RecommendedActions Check status of all enclosure power supplies. Problem
may be caused by a failed power supply. Add or
replace power supplies as necessary.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Power Supply Status changed to Non-Redundant.
EventCategory 17 (Primary Storage Power)
ProbableCause 89 (Power Supply Failure)