HP Insight Management WBEM Providers for HP integrated VMWare ESXi

Smart Array
4-4-14 HP_DeviceIndication: Controller Cache status—
Temporarily Disabled
Table 4-108 HP_DeviceIndication: Controller Cache status—Temporarily Disabled
Property name Property implementation
HP_AlertIndication
Summary Array Controller Cache Status is set to Temporarily
Disabled.
EventCategory 6 (Primary Storage)
ProbableCause 35 (Performance Degraded)
ProbableCauseDescription Array Controller Cache Status Changed to Temporarily
Disabled
NetworkAddresses Contains a list of all the IP addresses of the computer
system generating the indication
OSType SMX_OperatingSystem.OSType
OSVersion Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>
ProviderVersion 2.2.0.0
SystemFirmwareVersion Firmware version of the computer system generating
the indication
SystemSerialNumber Serial number of the computer system generating the
indication
SystemProductID Product ID of the computer system generating the
indication
SystemModel Model name of the computer system generating the
indication
SystemGUID Platform GUID of the computer system generating the
indication
ImpactedDomain 3 (Enclosure) for c-Class blade systems
4 (System) for all other systems
Note: When ImpactedDomain is 3 (Enclosure), the
properties indicated with (*) are populated.
BladeBay * HP_BladeCSLocation.LocationInformation[0]
BladeName * HP_ComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name
RackName * Rack name if one exists
RackUID * Rack Unique Identifier if one exists
SystemVirtualSerialNumber Conditional property containing the virtual system
serial number string when running in a Virtual Connect