HP Insight Management WBEM Providers for HP integrated VMWare ESXi
Smart Array
4-4-11 HP_DeviceIndication: Controller Battery status
changed to not fully charged
Table 4-105 HP_DeviceIndication: Controller Battery status changed to not fully charged
Property name Property implementation
VariableTypes[] String (1)
uint32 (5)
VariableValues[] FailureDescription short description of the failure
CacheSizeTotal HPSA_ArrayController.CacheSizeTotal
CacheSerialNumber
HPSA_ArrayController.CacheSerialNumber
HP_DeviceIndication
DeviceModel Array Controller Model string
4-4-12 HP_DeviceIndication: Controller Battery status
changed to Failed
Table 4-106 HP_DeviceIndication: Controller Battery status changed to Failed
Property name Property implementation
CIM_Indication
IndicationIdentifier GUID string generated at the time of indication
PerceivedSeverity 5 (major)
IndicationTime Time of indication
CIM_AlertIndication
Description A Smart Array controller battery status changed to
Failed.
AlertingMangedElement WBEM Path to SMX_SAArrayController class.
AlertingElementFormat 2 (CIMObjectPath)
AlertType 5 (Device Alert)
EventID 8
EventTime Time of the event or time of the indication if event time
unknown
ProviderName HP SmartArray
RecommendedActions Check battery connection - replace if necessary.
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication