ProLiant DL360 Server Maintenance and Service Guide

Diagnostics and Troubleshooting
4-32 Compaq ProLiant DL360 Server Maintenance and Service Guide
COMPAQ CONFIDENTIAL Codename: MIcroMachines Part Number: 169616-006 Last Saved On: 12/21/01 9:05 AM
Table 4-4: Memory Test Error Codes continued
Error Code Description Recommended Action
211-01
211-02
211-03
211-04
211-05
211-89
RAND test failed.
Error while saving test block.
Error while restoring test block.
Insufficient memory to perform the
test.
Failed inverted pattern compare,
but RAM was correct.
ECC error during noise test.
1. Replace the memory module/board and
retest.
2. Replace the system board and retest.
214-01
214-89
Data error during noise test
ECC error during testing
1. Replace the memory module/board and
retest.
2. Replace the system board and retest.
215 Nonfunctioning DC-DC converter
for processor X
Replace the DC-DC converter
(Processor Power Module).