ProLiant DL360 Server Maintenance and Service Guide
Diagnostics and Troubleshooting
Compaq ProLiant DL360 Server Maintenance and Service Guide 4-27
COMPAQ CONFIDENTIAL Codename: MIcroMachines Part Number: 169616-006 Last Saved On: 12/21/01 9:05 AM
Table 4-2: POST Error Messages continued
Error Code Audible Beeps
Probable Source of
Problem Recommended Action
1797-Drive Array
- Array
Accelerator Read
Error Occurred.
Data in Array
Accelerator has
been lost. Array
Accelerator is
disabled.
None Hard parity error while
reading data from
posted-writes memory.
Enable array accelerator.
1798-Drive Array
- Array
Accelerator Write
Error Occurred.
Array Accelerator
is disabled.
None Hard parity error while
writing data to
posted-writes memory.
Enable array accelerator.
1799-Drive Array
- Drive(s)
Disabled due to
Array Accelerator
Data Loss.
Select F1 to
continue with
logical drives
disabled.
Select F2 to
accept data loss
and to re-enable
logical drives.
None Volume failed due to loss of
data in posted-writes
memory.
Press the F1 key to continue
with logical drives disabled or
the F2 key to accept data loss
and re-enable logical drive.
Beeps only: 2
Long
2 long No valid memory is present
in the system.
Replace failed memory with
valid memory.
Beeps only: 2
Long + 2 Short
2 long, 2 short Power is cycled.
Temperature too hot.
Processor fan not installed
or spinning.
Check fan assembly.
(Run System
Configuration
Utility - F10 key)
None A configuration error
occurred during POST.
Press the F10 key to run
System Configuration Utility.
(RESUME - F1
key)
None As indicated to continue
Press the F1 key.