ProLiant DL360 Server Maintenance and Service Guide
Connectors, Switches, and Status Indicators
5-12 Compaq ProLiant DL360 Server Maintenance and Service Guide
COMPAQ CONFIDENTIAL Codename: MicroMachines Part Number: 169616-006 Last Saved On: 1/7/02 10:57 AM
Table 5-7: Hot-Plug SCSI Hard Drive LED Status Combinations
Activity Online Fault
Means
Flashing Flashing Flashing
Do not remove the drive. Removing
a drive during this process will
cause data loss.
The drive is part of an array being
selected by the Array Configuration
Utility.
-Or-
The Options ROMPaq is upgrading
the drive.
Off Off Off OK to replace the drive online if a
predictive failure alert is received (see
the following section for details) and
the drive is attached to an array
controller.
The drive is not configured as part of
an array.
-Or-
If this drive is part of an array, then a
powered-on controller is not
accessing the drive.
-Or-
The drive is configured as an online
spare.
Off Off On OK to replace the drive online.
The drive has failed, and has been
placed off-line.
Off On Off OK to replace the drive online if a
predictive failure alert is received (see
the following section for details),
provided that the array is configured
for fault tolerance and all other drives
in the array are online.
The drive is online and configured as
part of an array.
On or
Flashing
On Off
OK to replace the drive online if a
predictive failure alert is received
(see the following section for details),
provided that the array is configured
for fault tolerance and all other drives
in the array are online.
The drive is online and being
accessed.