Compaq ProLiant DL360 Generation 2 Server Setup and Installation Guide
F-2 Compaq ProLiant DL360 Generation 2 Server Setup and Installation Guide
Compaq Confidential – Need to Know Required
Writer: Ed Giblin Project: Compaq ProLiant DL360 Generation 2 Server Setup and Installation Guide Comments:
Part Number: 233832-001 File Name: q-appf Server Specifications.doc Last Saved On: 8/13/01 2:24 PM
Table F-1
Operating and Performance Specifications
continued
Dimensions
Rated input current 2.8 A (110 V) to 1.4 A
(220 V)
—
Rated input power 307 W —
BTUs per hour 1048 —
Power supply output
Rated steady-state power 180 W —
Maximum peak power 200 W —
Temperature range
Operating (See note) 10°C to 35°C 50°F to 95°F
Shipping (See note) -40°C to 70°C -40°F to 158°F
Relative humidity (noncondensing)
Operating (See note) 10% to 90% —
Non-operating (See note) 5% to 95% —
Maximum wet bulb temperature 28°C 82.4°F
Note: Operating temperature has an altitude derating of 1°C per 1,000 ft. No direct
sunlight. Storage maximum humidity of 95% is based on a maximum temperature of 45°C.
Altitude minimum for storage is 70 KPa.