Removal and replacement procedures 44
3. Install the heatsink.
4. Install the air baffle ("Air baffle" on page 36).
5. Install the BBWC battery pack, if removed ("BBWC battery pack" on page 35).
6. Install the access panel ("Access panel" on page 26).
7. Slide the server into the rack.
Processor
The server supports single- and dual-processor operation. Fan 2 is only required when processor 2 is installed
in the server. When only one processor is installed, always install the fan blank.
CAUTION:
To prevent possible server malfunction, do not mix processors of different speeds or
cache sizes. Refer to the label on the processor heatsink for a description of the processor.
IMPORTANT: Processor socket 1 must be populated at all times or the server does not function.