HP ProLiant DL360 G6 Server MSG
Removal and replacement procedures 40
Optional hard drive backplane assembly (top)
To remove the component:
1. Power down the server (on page 23).
2. Extend the server from the rack (on page 24).
3. Remove the access panel ("Access panel" on page 26).
4. Remove the hard drives from hard drive bays 5, 6, 7, and 8 ("SAS and SATA hard drive" on page 28).
5. Remove the BBWC battery pack, if installed ("BBWC battery pack" on page 35).
6. Remove the air baffle ("Air baffle" on page 36).
7. Remove all fan modules ("Fan module" on page 33).
8. Remove the fan blank ("Fan blank" on page 34).
9. Disconnect the hard drive data cable and the hard drive power cable from the optional hard drive
backplane and the system board ("Hard drive backplane cabling" on page 77).
10. Remove the optional hard drive backplane.
To replace the component, reverse the removal procedure.
Standard hard drive backplane assembly (bottom)
To remove the component:
1. Power down the server (on page 23).
2. Extend the server from the rack (on page 24).
3. Remove the access panel ("Access panel" on page 26).
4. Remove all hard drives ("SAS and SATA hard drive" on page 28).
5. Remove the BBWC battery pack, if installed ("BBWC battery pack" on page 35).
6. Remove the air baffle ("Air baffle" on page 36).
7. Remove all fan modules ("Fan module" on page 33).