ProLiant DL360 Generation 4p Server (SAS Model) Maintenance and Service Guide

Removal and replacement procedures 23
a.
Remove the riser board with the slot for full-length expansion boards.
b. Repeat the previous step for the riser board with the slot for half-length expansion boards, if
needed.
To replace the component, reverse the removal procedure.
Power converter module
To remove the component:
1. Power down the server ("Powering down the server" on page 11).
2. Remove all hot-plug power supplies ("Hot-plug AC power supply" on page 17).
3. Extend or remove the server from the rack ("Extending the server from the rack" on page 12).
4. Remove the access panel ("Access panel" on page 14).
5. Disconnect all internal power cables.
6. Remove the fan module ("Processor fan assembly" on page 19).