ProLiant DL360 Generation 4p Server (SAS Model) Maintenance and Service Guide

Removal and replacement procedures 17
Multi-bay device ejector
To remove the component:
1. Power down the server ("Powering down the server" on page 11).
2. Eject the multi-bay device or multi-bay device blank ("Multi-bay blank or device" on page 15).
3. Extend or remove the server from the rack ("Extending the server from the rack" on page 12).
4. Use a T-10 Torx screwdriver to remove the screws that secure the multi-bay device ejector to the
server chassis.
5. Press the tab on the side of the multi-bay device ejector to release it from the chassis.
6. Remove the multi-bay device ejector.
To replace the component, reverse the removal procedure.
Hot-plug AC power supply
This procedure assumes that the server is configured with two power supplies.
CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays
are populated with either a component or a blank.
To remove the component:
1. Perform one of the following:
If a conventional cable management solution is in place, unfasten the cable management solution
to access the power supply bays.
If the cable management arm is in place, access the rear panel ("Accessing the product rear
panel" on page 13).
2. Disconnect the power cord.