Table 6-1: Operating and Performance Specifications continued
Specifications
Power supply output
Rated steady-state power 325 W —
Maximum peak power 325 W —
Temperature range
Operating (Refer to note) 10°C to 35°C 50°F to 95°F
Shipping (Refer to note) -40°C to 60°C -40°F to 140°F
Relative humidity (noncondensing)
Operating (Refer to note) 10% to 90% —
Nonoperating (Refer to note) 5% to 95% —
Maximum wet-bulb temperature 28°C 82.4°F
NOTE: Operating temperature has an altitude derating of 1°C per 304.8 M
(1,000 ft). No direct sunlight. Storage maximum humidity of 95% is based on a
maximum temperature of 45°C. Altitude minimum for storage is 70 KPa.