System Unit
Table 6-1: System Unit Specifications
Dimensions
Height (without feet) 4.19 cm 1.65 in
Depth 65.45 cm 25.75 in
Width 42.55 cm 16.75 in
Weight (maximum) 11.81 kg 26 lb
Weight (no drives installed) 9.54 kg 21 lb
Input requirements
Rated input voltage 100 VAC to 240 VAC
Rated input frequency 50 Hz to 60 Hz
Rated input current 2.8 A (110 V) to 1.4 A (220 V)
Rated input power 307 W
BTUs per hour 1048
Power supply output
Rated steady-state power 180 W
Maximum peak power 200 W
Temperature range
Operating (See note) 10°C to 35°C 50°F to 95°F
Shipping (See note) -40°C to 70°C -40°F to 158°F
Relative humidity
(noncondensing)
Operating (See note) 10% to 90%
Non-operating (See note) 5% to 95%
Maximum wet bulb
temperature
28°C 82.4°F
Note: Operating temperature has an altitude derating of 1°C per 1,000 ft. No direct sunlight.
Storage maximum humidity of 95% is based on a maximum temperature of 45°C. Altitude minimum
for storage is 70 KPa.