Compaq ProLiant DL360 Generation 2 Server Setup and Installation Guide

C-6 Compaq ProLiant DL360 Generation 2 Server Setup and Installation Guide
Compaq Confidential Need to Know Required
Writer: Ed Giblin Project: Compaq ProLiant DL360 Generation 2 Server Setup and Installation Guide Comments:
Part Number: 233832-001 File Name: n-appc Status LED Indicators.doc Last Saved On: 8/31/01 11:45 AM
Table C-3
Hot-Plug Hard Drive LED Indicator Status Combinations
Activity Online Fault
Condition
On Off Off
Do not remove the drive. Removing a drive
during this process will cause data loss.
The drive is being accessed and is not configured
as part of an array.
On Flashing Off
Do not remove the drive. Removing a drive
during this process will cause data loss.
The drive is rebuilding or undergoing capacity
expansion.
Flashing Flashing Flashing
Do not remove the drive. Removing a drive
during this process will cause data loss.
The drive is part of an array being selected by the
Array Configuration Utility.
-Or-
The Options ROMPaq is upgrading the drive.
Off Off Off OK to replace the drive online if a predictive
failure alert is received and the drive is attached
to an array controller.
The drive is not configured as part of an array.
-Or-
If this drive is part of an array, then a powered-on
controller is not accessing the drive.
-Or-
The drive is configured as an online spare.
Off Off On OK to replace the drive online.
The drive has failed, and has been placed
off-line.
continued