HP ProLiant Storage Server User Guide (440584-001, February 2007)
Table 15 DL320s SAS and SATA hard drive LED combinations
Online/activity
LED (green)
Fault/UID LED
(amber/blue)
Status
On, off, or flashing
Alternating am
ber
and blue
The drive has failed, or a predictive failure alert has been
received for this drive; it also has been selected by a
management application.
On, off, or flashing
Steadily blue The d rive is operating normally, and it h as been selected by a
management application.
On
Amber, flashing
regularly (1 Hz)
A predictive failure alert has been received for this drive.
Replace the drive as soon as possible.
On
Off
The drive is online, but it is not active currently.
Flashing regularly
(1 Hz)
Amber, flashing
regularly (1 Hz)
Do not remove t he drive. Removing a drive may terminate the
current operation and cause data loss. The drive is part of an
array that is undergoing capacity expansion or stripe migration,
but a predictive failure alert has been received for this drive. To
minimize the risk of data loss, do not replace the drive until the
expansion or migration is complete.
Flashing regularly
(1 Hz)
Off
Do not remove t he drive. Removing a drive may terminate the
current operation and cause data loss. The drive is rebuilding,
or it is part of an array that is undergoing capacity expansion
or stripe migration.
Flashin
girregularly
Amber, flashing
regularly (1 Hz)
The drive is active, but a predictive failure alert has been
received for this drive. Replace the drive as soon as possible.
Flashing irregularly
Off
The drive is active, and it is operating normally .
Off
Steadily amber
A critical fault condition has been identified for this drive, and
the controller has placed it offline. Replace the drive as soon
as possible.
Off Amber, flashing
regularly (1 Hz)
A predictive failure alert has been received for this drive.
Replace the drive as soon as possible.
Off Off The drive is offline, a spare, or not configured as part of a n
array.
128 Server components