HP ProLiant Storage Server Release Notes (5697-6313, February 2007)
Additional applications and utilities
Issue:
JRE-dependent applications or web s ites prompt for JVM installation, or it is not properly
displayed
Description
A web site or app
lication that is dependent on Java Virtual M achine (JVM) is not
displayed pro
perly with Internet Explorer. A message prompts you to install JVM.
Workaround Uninstall the Java Runtime Environment (JRE) using the Control Panel an d Add or
Remove Programs. Reinstall th e JRE from the c:\hpnas\components\JRE
folder.
Issue:
VDS provider for MSA does no t refresh after volume creation fails
Description
Creating a LUN and volume using the Create a New LUN wizard using Storage
Manager for SAN results in the volume creation failing and displays a warning
icon on the created volume in the Storage Manager for SAN user interface.
The warning icon continues to display even after closing and re-opening the HP
Storage Ser ver Management console. Attempti ng to delete the LUN results in the
Storage Manager for SAN user interface becoming unresponsive and unable to
proceed past the delete LUN dialog box.
Workaround
Do one of t
he following:
• Restart
the system to load the LUNs and to refresh Storage Manager for SAN.
• Use the A
rray Configuration Utility (ACU) to create the LUN on the MSA, and
then use
the D isk Manager utility on t he Windows storage server to create
the LUN
volume.
Issue:
Storag
e Manager for SAN stops responding when Subsystem is selected
Description
When Subsystem is clicked in Storage Manager for SAN, the system stops
responding and displays the message MMC has detected an error in a
snap-in and will unload it.Thisbehaviorisseenonlywhenanyofthe
MSA subsystem volumes are being expanded.
Workaround
Use the Array Configuration Utility (ACU) to access the MSA subsystem when
volumes are being expanded.
Issue:
NfsSvr logs an error in the event log
Desc
ription
On sy
stems with Windows Storage Server 2003 R2, the event log may contain an
error stating that Ser ver for NFS failed to initialize on a non-existent drive letter.
For example:
Event Type: ErrorEvent
Source: NfsSvr
Event Category: None
Event ID: 1066
Description: Server for NFS failed to initialize
on volume with drive letter F:
Workaround
This error does not affect the performance of NFS. The issue will be resolved in a
later HP ProLiant Storage Server release.
S
ystem installation and recovery process
This section describes issues related to installing the operating system on a storage server or performing
t
he recovery process.
Storage Server release notes