ProLiant DL320 Setup and Installation Guide
Server Error Messages C-3
Compaq Confidential – Need to Know Required
Writer: Gilbert Saldivar Project: Compaq ProLiant DL320 Setup and Installation Guide Comments:
Part Number: 203836-001 File Name: k-appc Server Error Messages.doc Last Saved On: 8/1/00 3:58 PM
Table C-1
POST Error Messages
continued
Error Code Audible Beeps Probable Source of
Problem
Action
102-System Board
Failure
This is an
unrecoverable error.
Your computer needs
to be serviced.
None 8237 DMA
controllers, 8254
timers, etc.
Replace the system board. Run the
server setup utility.
162-System Options
Not Set
Your system
configuration has
changed since your
last boot (addition of
a hard drive, etc.), or
a loss of power to
the Real-Time Clock
has occurred. The
Real Time Clock will
lose power if the
onboard battery is
not functioning
correctly. Pressing
F1 will record the
new configuration. If
this message
persists, you may
need to replace the
onboard battery.
2 short Configuration
incorrect.
Run the server setup utility and
correct.
163-Time & Date Not
Set
The system time is
invalid. This may be
a result of a loss in
battery power. Set
the correct time and
date through your
operating system. If
this message
persists, you may
need to replace the
onboard battery.
2 short Invalid time or date
in configuration
memory.
Run the server setup utility and
correct.
continued