ProLiant DL320 Server Maintenance and Service Guide
Removal and Replacement Procedures
2-38 Compaq ProLiant 320 Server Maintenance and Service Guide
COMPAQ CONFIDENTIAL Codename: DarkStar-T Part Number: 203834-003 Last Saved On: 12/28/01 9:29 AM
Power Supply
IMPORTANT: A “Fan 6 Error” indicates an error from one of the power supply fans. When this error
occurs, you must replace the entire power supply unit.
To remove the power supply:
1. Power down the server. See “Powering Down the Server” in this chapter.
2. Remove the access panel. See “Server Access Panel” in this chapter.
3. Remove the PCI riser board assembly. See “PCI Riser Board Assembly” in this chapter.
4. Remove the center wall. See “Center Wall” in this chapter.
5. Disconnect the hard drive power cables from the hard drives
.
6. Disconnect the power supply cable from the power supply connector on the system board
by pressing the locking tab on the side of the connector and pulling upwards .
7. Remove the two Phillips-head screws that secure the power supply unit to the chassis
.
8. Slide the power supply away from the back of the chassis and lift it from the server
.
3
2
1
1
4
3
Figure 2-32: Removing the power supply
Reverse steps 1 through 8 to replace the power supply.