ProLiant DL320 Server Maintenance and Service Guide

Removal and Replacement Procedures
2-24 Compaq ProLiant 320 Server Maintenance and Service Guide
COMPAQ CONFIDENTIAL Codename: DarkStar-T Part Number: 203834-003 Last Saved On: 12/28/01 9:29 AM
Ultra ATA/100 Controller Module
To remove the ATA module:
1. Power down the server. See Powering Down the Server in this chapter.
2. Remove the access panel. See Access Panel in this chapter.
CAUTION: Prevent damage to the connector pins by lifting the ATA module evenly and with
equal pressure on the board. Tilting the board causes the connector pins to bend.
3. Remove the ATA module by pinching the tops of the support posts and carefully
lifting the ATA module from the system board
.
4. Disconnect the ATA cables from the ATA controller connectors on the module
.
1
3
2
3
Figure 2-18: Removing the ATA module from the system board
(center wall removed for clarity)
To replace the ATA module, reverse steps 1 through 4, ensuring that the ATA module seats
securely on the support posts.