HP ProLiant DL320s Server Maintenance and Service Guide

Removal and replacement procedures 21
Preparation procedures
To access some components and perform certain service procedures, you must perform one or more of the
following procedures:
Power down the server (on page 21).
If you must remove a server from a rack or a non-hot-plug component from a server, power down the
server.
Remove the server from the rack (on page 22).
If you are servicing internal components, remove the server from the rack.
Remove the access panel ("Removing and replacing the access panel" on page 22).
If you are servicing internal components, remove the access panel.
Remove the upper tray ("Removing the upper tray" on page 22).
If you are servicing internal components, remove the upper tray.
Power down the server
WARNING: To reduce the risk of personal injury, electric shock, or damage to the equipment,
remove the power cord to remove power from the server. The front panel Power On/Standby
button does not completely shut off system power. Portions of the power supply and some
internal circuitry remain active until AC power is removed.
IMPORTANT: If installing a hot-plug device, it is not necessary to power down the server.
1. Shut down the OS as directed by the OS documentation.
2. Press the Power On/Standby button to place the server in standby mode. When the server enters
standby power mode, the system power LED changes to amber.
3. Disconnect the power cords.
The system is now without power.
Extend the server from the rack
1. Power down the server (on page 21).
2. Disconnect all peripheral cables and power cords from the server rear panel.
3. Loosen the thumbscrews that secure the server faceplate to the front of the rack.
4. Extend the server on the rack rails.
WARNING: To reduce the risk of personal injury or equipment damage, be sure that the rack
is adequately stabilized before extending a component from the rack.
5. After performing the installation or maintenance procedure:
a. Slide the server fully into the rack.
b. Secure the server by tightening the thumbscrews.
6. Connect all peripheral cables and power cords.