ProLiant DL320 Generation 3 Server User Guide
Table Of Contents
- HP ProLiant DL320 Generation 3 Server User Guide
- Notice
- Contents
- Server component identification
- Server operations
- Powering up the server
- Powering down the server
- Preparation procedures
- Extending the server from the rack
- Removing the access panel
- Installing the access panel
- Removing the PCI riser board assembly
- Installing PCI riser board assembly
- Removing the hot-plug SATA backplane
- Removing the fan assembly
- Installing the fan assembly
- Server setup
- Hardware options installation
- Server cabling
- Server software and configuration utilities
- Battery replacement
- Troubleshooting
- Electrostatic discharge
- Regulatory compliance notices
- Regulatory compliance identification numbers
- Federal Communications Commission notice
- Declaration of conformity for products marked with the FCC logo, United States only
- Modifications
- Cables
- Mouse compliance statement
- Canadian notice (Avis Canadien)
- European Union regulatory notice
- Japanese notice
- BSMI notice
- Korean notice A&B
- Laser compliance
- Battery replacement notice
- Taiwan battery recycling notice
- Power cord statement for Japan
- Server specifications
- Technical support
- Acronyms and abbreviations
- Index

37
Hardware options installation
In this section
Introduction ..................................................................................................................................37
Memory options............................................................................................................................37
Hard drive options ........................................................................................................................39
Installing the CD-ROM drive assembly .......................................................................................43
Installing the DVD-ROM drive assembly ....................................................................................45
Installing the diskette drive assembly...........................................................................................45
Installing a PCI SCSI array controller or a PCI SCSI controller..................................................45
Introduction
If more than one option is being installed, read the installation instructions for all
the hardware options and identify similar steps to streamline the installation
process.
WARNING: To reduce the risk of personal injury from hot
surfaces, allow the drives and the internal system components to
cool before touching them.
CAUTION: To prevent damage to electrical components,
properly ground the server before beginning any installation procedure.
Improper grounding can cause electrostatic discharge.
Memory options
You can expand server memory by installing PC3200 DDR unbuffered SDRAM
DIMMs. The system supports up to four ECC DDR SDRAM DIMMs.
NOTE: By default, the server is set to Advanced ECC Support. Refer
to "HP ROM-Based Setup Utility (on page 53)" for more information.
The server supports standard memory configuration for maximum performance
with up to 4 GB of active memory (four 1-GB memory modules).