HP ProLiant DL165 G5p Server Maintenance and Service Guide
Contents 89
Table 12 POST Error Message
Error-Code Error Message Description / Corrective Action
04F Secondary Master Hard Disk
Error
The IDE/ATAPI device configured as Secondary Master
could not be properly initialized by the BIOS. This message
is typically displayed when the BIOS is trying to detect and
configure IDE/ATAPI devices in POST.
050 Secondary Slave Hard Disk
Error
The IDE/ATAPI device configured as Secondary Slave could
not be properly initialized by the BIOS. This message is
typically displayed when the BIOS is trying to detect and
configure IDE/ATAPI devices in POST.
051 Master Hard Disk Error The IDE/ATAPI device configured as Master in the 3rd IDE
controller could not be properly initialized by the BIOS.
This message is typically displayed when the BIOS is trying
to detect and configure IDE/ATAPI devices in POST.
052
Master Slave Disk Error The IDE/ATAPI device configured as Slave in the 3rd IDE
controller could not be properly initialized by the BIOS.
This message is typically displayed when the BIOS is trying
to detect and configure IDE/ATAPI devices in POST.
05E
Password check failed If user input incorrect password more than three times, then
display this error information and continue to boot.
Uncorrectable memory error System halts after displaying this message. If the problem
persists, contact Foxconn Customer Support.
Microcode Error BIOS could not find or load the CPU Microcode Update to
the CPU. The message is most likely to appear when a new
CPU is installed in a system board with outdated BIOS. In
this situation, you must update the BIOS to include the
Microcode Update for the new CPU.
Checking NVRAM Update
Failed
BIOS could not write to the NVRAM block. This message
appears when the FLASH part is malfunctioning.
Operating system not found
Operating system cannot be located on any of the
boot drives.
Verify that the priority boot drive has power and that
the IDE cable is connected properly.
Verify that the desired boot drive has power
Verify that the IDE cable is securely plugged into the
respective system board connectors.
Verify that the boot device is enabled in the Setup
Utility.
Verify that the boot device has an operating system
installed.
If the problem persists, contact your Foxconn
Customer Support provider.
0200 Failure Fixed Disk Fixed disk is not working or not configured properly.
Run Setup and check if the fixed-disk type is correctly
identified.
Check to see if fixed disk is attached properly.