HP ProLiant DL165 G5p Server Maintenance and Service Guide

Contents 42
Keep cables away from major heat sources like the heat sink.
Do not jam cables on top of expansion cards or memory modules. Printed circuit cards are not
designed to withstand excessive pressure.
Keep cables clear of sliding or moveable parts to prevent cutting or crimping.
When folding a flat ribbon cable, never fold to a sharp crease. Sharp creases may damage the
wires.
Some flat ribbon cables come pre-folded. Never change the folds on these cables.
Do not sharply bend any cable. A sharp bend can break the internal wires.
Never bend a SATA data cable tighter than a 30 mm (1.18 in) radius.
Never crease a SATA data cable.
Do not rely on components like the drive cage, power supply, or system cover to push cables
down into the chassis.
The next steps illustrate the removal of power cables from connectors P21, P23 and P24:
1. Squeeze on the top of the retaining latch attached to the cable end of the connector.
2. Grasp the cable end of the connector and pull it straight up.
CAUTION: Always pull the connector – NEVER pull on the cable. Pulling on the cable could damage
the cable and result in a failed power supply.
Figure 13 Unplugging power cables