HP ProLiant DL165 G5p Server Maintenance and Service Guide Part number 503256-002 Second edition April 2009
Legal notices © Copyright 2009 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. AMD is a trademark of Advanced Micro Systems, Inc.
Contents Customer self repair ............................................................................................................................... 5 Parts only warranty service........................................................................................................................ 5 Illustrated parts catalog ......................................................................................................................... 16 Mechanical components ...........................
Diagnostic tools and Setup Utilities ......................................................................................................... 75 BIOS Software....................................................................................................................................... 75 BIOS Setup Utility .................................................................................................................................. 75 Accessing the BIOS Setup Utility ............................
Customer self repair HP products are designed with many Customer Self Repair (CSR) parts to minimize repair time and allow for greater flexibility in performing defective parts replacement. If during the diagnosis period HP (or HP service providers or service partners) identifies that the repair can be accomplished by the use of a CSR part, HP will ship that part directly to you for replacement. There are two categories of CSR parts: • Mandatory—Parts for which customer self repair is mandatory.
Réparation par le client (CSR) Les produits HP comportent de nombreuses pièces CSR (Customer Self Repair = réparation par le client) afin de minimiser les délais de réparation et faciliter le remplacement des pièces défectueuses. Si pendant la période de diagnostic, HP (ou ses partenaires ou mainteneurs agréés) détermine que la réparation peut être effectuée à l'aide d'une pièce CSR, HP vous l'envoie directement.
Riparazione da parte del cliente Per abbreviare i tempi di riparazione e garantire una maggiore flessibilità nella sostituzione di parti difettose, i prodotti HP sono realizzati con numerosi componenti che possono essere riparati direttamente dal cliente (CSR, Customer Self Repair). Se in fase di diagnostica HP (o un centro di servizi o di assistenza HP) identifica il guasto come riparabile mediante un ricambio CSR, HP lo spedirà direttamente al cliente per la sostituzione.
Customer Self Repair HP Produkte enthalten viele CSR-Teile (Customer Self Repair), um Reparaturzeiten zu minimieren und höhere Flexibilität beim Austausch defekter Bauteile zu ermöglichen. Wenn HP (oder ein HP Servicepartner) bei der Diagnose feststellt, dass das Produkt mithilfe eines CSR-Teils repariert werden kann, sendet Ihnen HP dieses Bauteil zum Austausch direkt zu.
Reparaciones del propio cliente Los productos de HP incluyen muchos componentes que el propio usuario puede reemplazar (Customer Self Repair, CSR) para minimizar el tiempo de reparación y ofrecer una mayor flexibilidad a la hora de realizar sustituciones de componentes defectuosos.
Customer Self Repair Veel onderdelen in HP producten zijn door de klant zelf te repareren, waardoor de reparatieduur tot een minimum beperkt kan blijven en de flexibiliteit in het vervangen van defecte onderdelen groter is. Deze onderdelen worden CSR-onderdelen (Customer Self Repair) genoemd.
Reparo feito pelo cliente Os produtos da HP são projetados com muitas peças para reparo feito pelo cliente (CSR) de modo a minimizar o tempo de reparo e permitir maior flexibilidade na substituição de peças com defeito. Se, durante o período de diagnóstico, a HP (ou fornecedores/parceiros de serviço da HP) concluir que o reparo pode ser efetuado pelo uso de uma peça CSR, a peça de reposição será enviada diretamente ao cliente.
Contents 12
Contents 13
Contents 14
Contents 15
Illustrated parts catalog Mechanical components Table 1 Mechanical components spare parts list Item Description Spare part number Customer self repair 1 Top cover 454347-001 Mandatory1 2 Rails kit 454367-001 Mandatory1 3 Hard drive cage 4 Mandatory1 a. DL16x NHP 4HDD Cage 462421-001 b. DL16x Hot Plug 4HDD Cage 462422-001 Plastic & Hardware Spares Kit a. ODD bezel blank b.
Mandatory—Parts for which customer self repair is mandatory. If you request HP to replace these parts, you will be charged for the travel and labor costs of this service. 1 Optional—Parts for which customer self repair is optional. These parts are also designed for customer self repair. If, however, you require that HP replace them for you, there may or may not be additional charges, depending on the type of warranty service designated for your product.
Mandatory: Obligatorio—componentes para los que la reparación por parte del usuario es obligatoria. Si solicita a HP que realice la sustitución de estos componentes, tendrá que hacerse cargo de los gastos de desplazamiento y de mano de obra de dicho servicio. 1 Optional: Opcional— componentes para los que la reparación por parte del usuario es opcional. Estos componentes también están diseñados para que puedan ser reparados por el usuario.
Contents 19
System components with non-hot-plug HDD Table 2 System Components Spare Parts List Item Description Spare Part Number Customer Self Repair 1 System Fan 457873-001 Mandatory1 2 Backplane two bays SAS/SATA hard drive 452340-001 Optional2 3 Cable Assy USB 452338-001 Mandatory1 4 Cable SATA 250mm 452333-001 Mandatory1 5 Cable IDE ODD 454356-001 Mandatory1 6 Non-hot-plug SATA Hard Drive 353043-001 Mandatory1 7 Optical Disc Drive (ODD) 8 Mandatory1 SPS-DRV,9.
Table 2 System Components Spare Parts List Item 9 Description Spare Part Number Customer Self Repair SPS-DIMM, 4GB PC2-6400, 256Mx4, RoHS 501158-001 Mandatory1 SPS-DIMM, 8GB PC2-6400, 512Mx4, RoHS 501159-001 Mandatory1 Processors ,Opteron Series Optional2 SPS-IC, uP, Shanghai 2376 2.3GHz 75W 502922-001 Optional2 SPS-IC, uP, Shanghai 2380 2.5GHz 75W 500515-001 Optional2 SPS-IC, uP, Shanghai 2384 2.
Table 3 System Components Spare Parts List Item Description Spare Part Number Customer Self Repair 3 Cable Assy USB 452338-001 Mandatory1 4 Cable SAS Hard Drive 457874-001 Mandatory1 5 Cable IDE ODD 454356-001 Mandatory1 6 Optical Disc Drive (ODD) 7 8 Mandatory1 SPS-DRV,9.5mm,DVD-ROM,ROHS 403709-001 Mandatory1 SPS-DRV,9.
Mandatory: Obligatoire—Pièces pour lesquelles la réparation par le client est obligatoire. Si vous demandez à HP de remplacer ces pièces, les coûts de déplacement et main d'œuvre du service vous seront facturés. 1 Optional: Facultatif—Pièces pour lesquelles la réparation par le client est facultative. Ces pièces sont également conçues pour permettre au client d'effectuer lui-même la réparation.
autorizado realice la sustitución de estos componentes. Dichos componentes se identifican con la palabra “No” en el catálogo ilustrado de componentes. Mandatory: Verplicht—Onderdelen waarvoor Customer Self Repair verplicht is. Als u HP verzoekt deze onderdelen te vervangen, komen de reiskosten en het arbeidsloon voor uw rekening. 1 Optional: Optioneel—Onderdelen waarvoor reparatie door de klant optioneel is. Ook deze onderdelen zijn ontworpen voor reparatie door de klant.
• • • • • • Products serial number Products model name and number Applicable error messages Add-on boards or hardware model number and serial number Third-party hardware or software model number Operating system type and revision level Contents 25
Connectors, Switches, and LEDs This chapter contains illustrations and tables identifying and describing the connectors, switches, buttons, and LED indicators located on the front panel, rear panel, system board and hard drives of the HP ProLiant DL165 G5p server. Connectors and Components Front Panel Components Figure 1 Front panel components Item Description 1 Thumbscrews for rack mounting 2 Optical disk drive bay 3 Serial number pull tab 4 Two front USB 2.
Rear panel components Figure 2 Rear panel components Item Description 1 Power supply cable socket 2 PS/2 mouse port (green) 3 GbE LAN port for NIC2 4 Captive thumbscrew for top cover 5 Serial port (teal) 6 Full Height/Full Length expansion slot 7 T10/T15 Wrench 8 Thumbscrew for PCI cage 9 UID LED button 10 VGA port 11 HP LO100i Management LAN Port 12 Two rear USB 2.
System board components Figure 3 System board components 1 Designator Description J22 Top: PS/2 mouse port Bottom: PS/2 keyboard port 2 J16 Top: LAN port 2 Bottom: LAN port 1 3 CN21 Top: USB 2.0 port Bottom: USB 2.
Designator Description 11 XU3 Internal USB connector 12 J21 Password jumper 13 P10 18-Pin front panel port 14 P19 5-Pin system fan 6 header 15 J25 IDE channel 16 SATA SATA1,2,3,4 connector 17 P11 Front USB 2.
LED Indicators This section contains illustration and descriptions of internal and external status LED indicators located on the: • • • Front panel Rear panel System board These LED indicators aid in problem diagnosis by indicating the status of system components and operations of the server. Front panel LED indicators The front panel LED indicators allow constant monitoring of basic system functions while the server is operating.
Power LED Indicator The power status of the server is indicated by the bicolor LED on the front panel. Figure 5 Power LED indicator location Table 5 Power LED indicator status Component Status Description Power LED indicator Steady green The server is operating normally. Steady Amber The server is system off or in hibernation with A/C power. Off The server is system off without A/C power.
Hard drive activity LED indicator The status of hard drives installed in the server is indicated by the drive activity LED indicator located on the front panel of the server.
Table 6 Hard drive activity LED indicator status Item LED indicator Status Description Flashing green during a • drive activity (if command is outstanding • continually the indicator • is forced to flash at 4 Hz 50% duty cycle instead of solid off) The drive is currently performing an I/O activity. The drive is a member of a RAID volume. The drive is not in a replacement or failed state for any volumes that it is a member of (drive is online). • The drive is not rebuilding.
Rear panel LED indicators The LAN port on the rear panel has two LED indicators that allow monitoring of network activity. Figure 7 LAN/LED indicators location Table 7 LAN/LED indicator states Item 1 2 Component Status Description LAN activity status LED indicator Flashing green Ongoing network data activity. Off No network data activity or no connection. Steady green The LAN connection is using a GbE link. Steady amber The LAN connection is using 10Mbps/100 Mbps link. Off No connection.
System board LED indicator The system board contains one LED indicator for use during troubleshooting operations.
Removal and Replacement Procedures This chapter provides subassembly/module-level removal and replacement procedures for the HP ProLiant DL165 G5p server. Review the specifications of a new component before installing it to make sure it is compatible with the server. When you integrate new components into the system, record its model and serial number, and any other pertinent information for future reference.
• Use conductive field service tools. Pre-Installation Procedure Perform the steps below before you open the server or before you remove or replace any component. WARNING: Failure to properly turn off the server before you open the server or before your start installing/ removing components may cause serious damage as well as bodily harm. 1. Turn off the server and all the peripherals connected to it. 2.
• Do not route the power cord where it can be walked on or pinched by items placed against it. Pay particular attention to the plug, electrical outlet, and the point where the cord extends from the server. WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them. CAUTION: For proper cooling, do not operate the server without the access panel, baffles, expansion slot covers, or blanks installed.
Powering Down the Server The server does not completely power down when the power button on the front panel is pressed. The button toggles between On and Standby. The standby position removes power from most electronics and the drives, but some internal circuitry remains active. To completely remove all power from the system, disconnect all power cords from the server. To power down the server: 1. Shut down server as directed by the operating system documentation. 2.
Figure 9 Removing the Top Cover To reinstall the top cover: 1. Align the top cover to the chassis and then slide it toward the front panel to position it into place. 2. Once the cover is attached to the chassis, tighten the captive screw on the rear panel with a T-15 screwdriver. Figure 10 Reinstalling the Top Cover Top Middle Cover To remove the top middle cover: 1.
Figure 11 Removing the Top Middle Cover To reinstall the top middle cover: 1. Align the top middle cover to the chassis. 2. Fasten the four screws (one on each side of the chassis and two on the top middle cover) to securing the top middle cover to the chassis. Figure 12 Reinstalling the Top Middle Cover Drives The server supports up to five drive bays – four drive bays for 3.5-inch hard disks drive and one drive bay for optical disc drive.
• • Keep cables away from major heat sources like the heat sink. • • Keep cables clear of sliding or moveable parts to prevent cutting or crimping. • • • • • Some flat ribbon cables come pre-folded. Never change the folds on these cables. Do not jam cables on top of expansion cards or memory modules. Printed circuit cards are not designed to withstand excessive pressure. When folding a flat ribbon cable, never fold to a sharp crease. Sharp creases may damage the wires. Do not sharply bend any cable.
Cable Connections The following table provides information about switching power supply cable connector labels.
Drive Bay Configuration The server supports a maximum of five drive bays – four bays for 3.5-inch hard disk drives and one drive bay for an optical media drive. Figure 14 System Drive Bays Item Description 1 Optical Media Device Bay 2 3.5 Inch Hard Disk Drive Bays (four) The HDD bays support both non-hot-plug and hot-plug SATA drives, as well as hot-plug SAS drives. Optical Media Device Bay The optical media device bay supports the installation of a 9.5mm DVD/CD R/RW ROM optical drive.
Figure 15 DVD/CDRW-ROM Location Pre-installation Procedure: 1. Turn off the server and all the peripherals connected to it. 2. Unplug all external cables and AC power cords. If necessary, label each one to expedite reassembly. 3. Remove unit from rack and place on a flat surface. 4. Remove the top cover. 5. Remove the top middle cover. To remove the bezel blank: 1. Pull the bezel blank out of the carrier. CAUTION: Do not discard the bezel blank.
Figure 16 Removing the Bezel Blank To install the optical drive: 1. Slide the optical drive assembly into the chassis. Figure 17 Installing the optical drive 2. Remove the middle cover and connect the IDE data and power cables to their corresponding connectors on the optical drive.
Figure 18 Connecting the cables To remove the optical drive: 1. Remove the top middle cover and then unplug the ODD cable and power cable, uplift the spring latch securing the optical drive carrier to the chassis. 2. Push the optical drive toward the front of the unit. 3. Pull the optical drive out of the chassis. Figure 19 Removing the optical drive IMPORTANT: If you removed an optical drive without plans of installing a new one, you must reinstall the blank to maintain proper system airflow.
Hard Drives The drive bays on the front panel can accommodate up to four hard drives. You can install either SAS hard drives or SATA hard drives in the server. Hard drives installed in the server are labeled from Device 1 to Device 4, from left to right, when viewed from the front of the server. Figure 20 Hard drive bays configuration Item Description 1 1st SAS/SATA Hard Drive 2 2nd SAS/SATA Hard Drive 3 3rd SAS/SATA Hard Drive 4 4th SAS/SATA Hard Drive To install a hard drive: 1.
Figure 21 Removing the hot-plug hard drive blank IMPORTANT: Do not discard the hard drive blank. If the drive is removed in the future, you must reinstall the hard drive blank to maintain proper system airflow. 2. Install a hard drive. a. Push the hard drive assembly into the drive bay until it stops. b. Press the HDD carrier latch inward until it clicks. Figure 22 Installing the hot-plug hard drive assembly To remove hard drive: 1. Press the hard disk carrier button to release the ejector lever. 2.
Figure 23 Removing the hot-plug hard drive To install a non-hot-plug hard drive: 1. Remove four screws from the top part of the carrier. 2. Put the non-hot-plug hard drive disk into the carrier. 3. Fasten the HDD to the carrier using the screws (two on each side).
Figure 25 Fastening the non-hot-plug hard drive disk to the carrier To install a non-hot-plug hard drive in the server: 1. Remove the hard drive blank from front of system if installed. 2. Push the hard drive assembly into the drive bay until it stops. 3. Fasten the screw with the T-15 wrench provided to secure the hard drive to the chassis. 4. Connect the cabling from the HDD backplane to the drive using the cables provided.
Figure 27 Removing the non-hot-plug hard drive assembly To remove a non-hot-plug hard drive disk from the carrier: 1. Loosen the four screws on the carrier (two on each side). 2. Lift the hard drive from the carrier. Figure 28 Removing the non-hot-plug hard drive assembly SAS/SATA HDD Backplane The following figures show the front and back side of the backplane.
Figure 29 Backplane connectors (component side) Item Description 1 Screw Holes 2 LED indicators 3 Headers for Hard Drive Figure 30 Backplane connectors (solder side) Item Description 1 Header for backplane aligns to backplane inter-connection 2 SATA Signal Cable Connector 3 SGPIO header Contents 53
Item Description 4 PSOC F/W programming header 5 4- pin power connector WARNING: Ensure that the system is powered off and all power sources have been disconnected from the server. Voltages are present at various locations within the server whenever an AC power source is connected. This voltage is present even when the main power switch is in the off position. To remove the backplane: 1. Remove all drives out of the drive bays.
Figure 32 Removing the backplane To install the backplane: 1. Orient the backplane so that the notches on the board align with the two hooks on the drive cage and press the board down until it clicks into place. 2. Secure the backplane with two screws. Figure 33 Installing the backplane 3. Install all cables including optical drive cables.
System Board Configuration Processor HP ProLiant DL165 G5p Server supports two AMD dual and quad core processors. If a single processor is installed, then use socket 0. When two processors are used, the server supports boot functions through the processor installed in processor socket 0. However, if processor 0 fails, the system can’t boot up, and if processor 1 fails, the system will automatically boots from processor 0 and provides a processor failure message.
Figure 35 Removing the air baffle To remove the heat sink: 1. Loosen the two mounting pins. 2. Lift the heat sink away from the system board. CAUTION: Place heat sink down in an upright position with the thermal patch facing upward. Do not let the thermal patch touch the work surface.
To remove a processor: 1. Disengage the load lever. 2. Lift the retention plate to expose the socket body. 3. Grasp the processor by its edges and lift it out of its socket. Figure 37 Removing the processor CAUTION: The pins of the socket are very fragile. Do not bend or damage them. CAUTION: Place the processor on a static-dissipating work surface or in an anti-static bag.
Figure 38 The bottom of heat sink CAUTION: Never touch the bottom of the processor; any contaminant could prevent the mounting pads from making contact with the socket. CAUTION: Applying too much grease creates a gap between the contact surfaces, significantly reducing the ability of the heat sink to draw out heat. Installing the heat sink with excessive grease can also cause the grease to spread over the processor pins or the system board base, which can cause electrical shorts that damage the system.
Figure 39 Installing the processor CAUTION: To prevent overheating or a possible system crash, use only a heat sink model specified for the HP ProLiant DL165 G5p server. To install the heat sink: 1. Properly align the heat sink mounting pins to the system board mounting holes. 2. Tighten the mounting pins clockwise to secure the heat sink connection to the system board. Figure 40 Installing the heat sink To install the air baffle: 1. Gently place in the air baffle.
Figure 41 Installing the air baffle Memory The following guidelines must be followed when memory modules are added or replaced: Supports DDR2 667 or 800 MHz SDRAM with Advanced ECC (Registered) PC2-5300. • Supported configuration. ○ Two DIMMs per processor: J107, J106 for CPU1; J14, J13 for CPU0. ○ Four DIMMs per processor: J107, J106, J105, J104 for CPU1; J14, J13, J12, J11 for CPU0. ○ Six DIMMs per processor: J107, J106, J105, J104, J103, J102 for CPU1; J14, J13, J12, J11, J10, J9 for CPU0.
NOTE: Before installing the memory, remove the air baffle first, for detailed procedure, refer to the ‘Processor’ section in this chapter. To remove memory module: 1. Completely open the holding clips securing the module. 2. Gently pull the memory module upward to remove it from the slot. Figure 43 Removing a memory module CAUTION: Place the memory module on a static-dissipating work surface or inside of an anti-static bag. To install a memory module: 1.
Figure 44 Installing a memory module CAUTION: The memory slots are structured to ensure proper installation. If you insert a memory module but it does not fit easily into the slot, you may have inserted it incorrectly. Double-check the orientation of the module and reinsert. If the holding clips do not close, the module is not inserted correctly. PCI Expansion Card System Board PCI Expansion Slot There is a PCI expansion slot on the system board.
Figure 45 System board PCI expansion slot Item Component Designator Component Function 1 J33 Full Height\Full Length PCI slot Supports a PCIe Riser Card PCI Riser card Expansion Slot The PCI Express riser card attached to the PCI cage convert the functionality of the system board expansion slot to the slot positioned at a 90° angle from the system board.
NOTE: Disconnect all cables connecting an existing expansion board to the system board. 1. Loosen the two captive screws that secure the PCI cage to the chassis. 2. Lift the PCI cage away from the chassis. Figure 47 Removing the PCI cage Installing PCIe Riser Board The system supports up PCIe riser board. Use only HP supported expansion boards that meets the following specifications: To remove the PCIe riser card: 1. Loosen the two screws securing the riser card to the PCI cage. 2.
Figure 48 Removing the PCIe riser card To install the PCIe riser card: 1. Align the two riser card slots to the standoff on the PCI cage, and then push the card up. 2. Install and tighten the two screws that secure the riser card to the PCI cage. Figure 49 Installing the PCIe riser card To remove the slot cover: 1. Loosen the screw(s) that secure(s) the slot cover(s) to the chassis. 2. Remove the slot cover(s) on the PCI cage. CAUTION: Do not discard the slot cover.
Figure 50 Removing the slot cover To install the PCI card: 1. Slide the expansion board into the slot, aligning the board with its matching connector. Firmly press the board to seat it properly on the slot. 2. Tighten the screw that secures the card to the PCI cage. Figure 51 Installing the PCI card To reinstall the PCI cage: 1. Installing the PCI riser card into the system. a. Align the PCI card with the open expansion slot. b.
Figure 52 Installing the PCI cage with PCI card Figure 53 Securing the PCI cage 4. Connect the necessary cable(s) to the board. System Battery The server uses nonvolatile memory that requires a battery to retain system information when power is removed. This 3-volt lithium coin cell battery is located on the system board.
Figure 54 System battery location WARNING: Note the following reminders when replacing the system battery: • Replace the battery with the same type as the battery recommended by HP. Use of another battery may present a risk of fire or explosion. • A risk of fire and chemical burn exists if the battery is not handled properly. Do not disassemble, crush, puncture, or short external contacts, or expose the battery to temperatures higher than 60°C (140°F). • Do not dispose of used battery in water or fire.
Figure 55 Replacing the battery System Board Removal and Replacement Procedure To remove the system board: 1. Remove the top cover. 2. Loosen the nine screws that secure the system board to the chassis. 3. Slide the system board back, up and out of the chassis. Remove the system board from the chassis. Figure 56 Removing the system board To replace the system board: 1. Align the system board I/O connectors to their openings and slide the system board into place.
Figure 57 Installing the system board Power Supply Unit (PSU) Located on the rear panel of the server power supply is a standard autoranging 1200-watt hot-plug PSU with PFC (power factor correction) function. Figure 58 Hot-plug Power Supply Unit To remove the hot-plug power supply: 1. Disconnect the power cable connecting the hot-plug power supply and the mother board. 2. Press the purple colored handle. 3. Slide the hot-plug power supply out of the power supply bay.
Figure 59 Removing the hot-plug power supply To replace the hot-plug power supply: 1. Align the hot-plug power supply cage connector with the open slot of power supply, and slide the hot-plug power supply into the power supply bay until it snaps into place. 2. Snap the latch cover over port colored handle. Latch cover only installs one way. Figure 60 Installing the hot-plug power supply System Fan The server has six system fans located on the chassis’ center wall.
Figure 61 System fan connections Device number Connector System fan 1 P12 on the system board System fan 2 P18 on the system board System fan 3 P13 on the system board System fan 4 P15 on the system board System fan 5 P17 on the system board System fan 6 P19 on the system board System fans 1 to 5 are for the memory modules and processors, while system fan 6 is for the PCI slots and system chipsets.
Figure 62 Removing the system fan To install the system fan: 1. Put the fan cable through the system fan bracket and secure the cable using the cable clip on the chassis. 2. Hold the system fan and press it into the fan bracket. 3. Connect the fan cable to its corresponding board connector.
Diagnostic tools and Setup Utilities This chapter provides an overview of the Power-On Self-Test (POST), the POST error messages, and BIOS, SAS and SATA setup utilities. BIOS Software The server uses BIOS to boot up the system. BIOS software is a ROM-based firmware that allows reliability, manageability, and connectivity for server platforms. This software contains a set of programs permanently stored in an EEPROM chipset located on the system board.
Navigating through the Setup Utility Use the keys listed in the legend bar on the right of the Setup screen to navigate through the various menu and submenu screens of the Setup Utility. Table 11 lists these legend keys and their respective functions. Table 11 Setup Utility Navigation Keys Key Function ← and → Move between selections on the menu bar. ↑ and ↓ Move the cursor to the field you want. The currently selected field is highlighted.
Figure 64 Setup utility general help screen Press F1 to get the general help message box.
Setup Utility Menu Bar The BIOS Setup Utility provides a menu bar with the menu selections. The menu bar choices are described in the topics below.
Figure 66 Main menu of the BIOS setup utility Use this menu to set the system time and date, and configure the following items: • • • • • • • • View BIOS build date and version. View CPU type / CPU speed. View System memory size. View System serial number. View MAC address for the embedded NIC. Set Server Asset Tag. Set system time and date. Set boot features: ○ ○ ○ ○ Enable or Disable the BIOS summary display. Turn on or off Bootup Num-Lock.
Advanced Menu Figure 67 Advanced menu of the BIOS setup utility WARNING: Incorrect settings may cause the server to malfunction. To correct the settings, press F9 key to restore the default settings. • • • • • • • • • CPU Configuration --- Configure and view the current CPU configuration and settings. IO Device Configuration --- Configure Super IO chipset SCH4307. S-ATA Configuration --- Configure Server Works HT 1000 SATA. ACPI Configuration --- Section for Advanced ACPI configuration.
Figure 68 IPMI submenu of the BIOS setup utility • • • • SEL Configuration --- Configure of the BMC System Event Log. • Hardware health information --- Select to get information about CPU temperature, ambient temperature, CPU fan speed, system fan speed and chassis fan speed. Serial Port Configuration --- Select to configure system serial ports. LAN Configuration --- Select for LAN configuration. Watchdog Configuration --- Select to configure POST Watchdog Timer Action and BMC Watch Dog Time Out.
Boot Menu Figure 69 Boot menu of the BIOS setup utility Use this menu to configure the boot priority. • Boot Device Priority --- Use this screen to specify the order in which the system checks for a boot device. • Embedded NIC Port 1 PXE --- Use this screen to configure the embedded NIC Port 1 PXE boot option. The default is enabled. • Embedded NIC Port 2 PXE --- Use this screen to configure the embedded NIC Port 2 PXE boot option. The default is disabled.
Security Menu Figure 70 Security menu of the BIOS setup utility 1 Contents 83
Figure 71 Security menu of the BIOS setup utility 2 Contents 84
Use this menu to configure the following items: • • Administrator Password --- Display if an administrator password is Set or Not. Change Administrator Password --- Allows you to access and change all settings in the Setup Utility. The administrator password allows you to configure access for system users. To set a new administrator password: 1. In the Security screen, select a set password field - Change Administrator Password, and then press Enter. 2.
Exit Menu Figure 72 Exit menu of the BIOS setup utility Use this menu to save changes or discard changes. When you save and exit, the server reboots. • Save Changes and Exit --- Save the changes you have made and exit the BIOS Setup Utility. (You can also press F10 key.) • Discard Changes and Exit --- Exit the BIOS Setup Utility without saving the changes you have made. (You can also press Esc key.) • • Discard Changes --- Discard any changes you have made. (You can also press F7 key.
○ ○ ○ ○ Create a bootable ROMPaq CD. ROMPaq Diskette Flat Files. Create a label for the ROMPaq diskette. Network ROM Flashing Capabilities. 4. Reboot DL165 G5p Server with one of the above bootable devices and make sure the BIOS setting allows booting from the USB disk. 5. Follow the on-screen instructions to finish the flashing of the BIOS.
POST Error Indicators When POST detects a system failure, it displays a POST error message. POST Error Message Definition Whenever a non-fatal error occurs during POST, an error message describing the problem appears onscreen. These error messages are displayed in normal video (white text on black background), and show the details of the error.
Table 12 POST Error Message Error-Code Error Message 04F Secondary Master Hard Disk Error The IDE/ATAPI device configured as Secondary Master could not be properly initialized by the BIOS. This message is typically displayed when the BIOS is trying to detect and configure IDE/ATAPI devices in POST. 050 Secondary Slave Hard Disk Error The IDE/ATAPI device configured as Secondary Slave could not be properly initialized by the BIOS.
Table 12 POST Error Message Error-Code Error Message 0202 CPU mismatch detected! Fatal Error…System Halted. Description / Corrective Action The Error Message will be display when install two CPU on motherboard as follow: Slot I : NPT Slot II : Barcelona Note: The server can’t boot if install two CPU on motherboard as follow: Slot I : Barcelona Slot II :NPT 0210 Stuck key Stuck key on keyboard. 1 Locate the stuck key on your keyboard and release it. 2 Reboot the server.
Table 12 POST Error Message Error-Code Error Message Description / Corrective Action 0280 Previous boot incomplete – Default configuration used Initial boot up failed. BIOS automatically loads the default system values, then boot again. 0281 Memory size found by POST differed from CMOS The user has added or removed a memory module, thus a memory size that is different from the previous boot up. 02F5 DMA test failed The DMA control test failed.
Physical and Operating Specifications This chapter provides physical and operating specifications for the HP ProLiant DL165 G5p server.
Table 14 Physical Dimensions Item Description System board platform ATX (Advanced Technology Extended) System board dimension 12’’ x 13.5’’ Server dimensions Rack 448W * 43H * 698.7D (mm) Server weight Basic Configuration ( excludes keyboard and monitor): 19 kg Table 15 Environmental Specifications Item Description Temperature: Operating +10 to +35° (+50 to +95°F) Non-operating -30 to 60° (-22 to 140°F) Storage -30 to 60° (-22 to 140°F) Wet-bulb temperature 38.7° (101.
Table 16 Hot-Plug Power Supply Specifications Item Description BTU rating N/A Power supply output power: Rated steady state power Maximum peak power 1200W N/A Temperature range: Operating Shipping +5 to +50 –40 to +85 Relative humidity: Operating Non-operating 5% to 95% relative humidity, non-condensing.
Index cable management, 41 A drive bay configuration, 44 AC power hard drives, 48 power-down procedures, 39 optical media drive, 44 air duck installing, 60 E removing, 56 electric shock symbol, 38 AMIBIOS Setup Utility warning, 37 BIOS settings loss, 69 exploded view B mechanical components, 16 backplane installing, 55 H removing, 54 hard drive battery replacement warnings, 69 bezel blank removing, 45 BIOS Setup Utility installing, 48 removing, 49, 51 Hard drive cage spare part number,