HP ProLiant DL165 Generation 5 Software Configuration Guide
System BIOS configuration 15
SuperIO Configuration submenu
Figure 8 SuperIO Configuration submenu
Table 7 SuperIO Configuration submenu fields
Option
Description
Disabled Set this value to prevent the serial port from accessing any system resources. When this option
is set to Disabled, the serial port physically becomes unavailable
3F8/IRQ4 Set this value to allow the serial port to use 3F8 as its I/O port address and IRQ 4 for the
interrupt address. This is the default setting. The majority of serial port 1 or COM1 ports on
computer systems use IRQ4 and I/O Port 3F8 as the standard setting. The most common serial
device connected to this port is a mouse. If the system will not use a serial device, it is best to
set this port to Disabled.
3E8/IRQ4 Set this value to allow the serial port to use 3E8 as its I/O port address and IRQ 4 for the
interrupt address. If the system will not use a serial device, it is best to set this port to
Disabled.
2E8/IRQ3 Set this value to allow the serial port to use 2E8 as its I/O port address and IRQ 3 for the
interrupt address. If the system will not use a serial device, it is best to set this port to
Disabled.
2F8/IRQ3 Set this value to allow the serial port to use 2F8 as its I/O port address and IRQ 3 for the
interrupt address. If the system will not use a serial device, it is best to set this port to
Disabled.