ProLiant DL145 Generation 3 Server Maintenance and Service Guide

Physical and operating specifications 71
Table 8 Hardware specifications
Item Description
Power supply unit (PSU) 1U 650-watt PSU
System management function IPMI 2.0-compliant with dedicated 10/100 Mbps LAN port for online system
health monitoring
Thermal solution Three system fans for the memory modules, processors, system chipsets, and
expansion slots
Two PSU fans
Table 9 Physical dimensions
Item Description
System board dimensions
Length
Width
381 mm (15 in)
325 mm (12.8 in)
Server dimensions
Height
Width
Depth
43.2 mm (1.7 in)
426.7 mm (16.786 in)
675.6 mm (26.6 in)
Server weight (maximum configuration) 15.87 kg (35 lb)
Table 10 Environmental specifications
Item Description
System inlet temperature
Operating
Non-operating (unpacked)
Storage (unpacked)
Shipping (packed)
10° to 35° C (50° to 95° F)
0° to 50° C (32° to 122° F)
5° to 40° C (41° to 104° F)
-40° to 70° C (-40° to 158° F)
NOTE: System performance may be reduced if operating above 30° C (86° F).
NOTE: Operating temperature has an altitude derating of 1° C per 300 m to 3000 m.
Relative humidity (non-condensing)
Operating
Non-operating
10% to 90%, 28° C (82.4° F) maximum wet-bulb temperature
5% to 95%, 38.7° C (101.7° F) maximum wet-bulb temperature
Altitude
Operating
Non-operating
3050 m (10,000 ft). This value may be limited by the type and number of
options installed.
9144 m (30,000 ft)
NOTE: The maximum allowable altitude change rate is 457 m/min (1500 ft/min)
Acoustic noise
Operating minimum (random seeks to
fixed disks)
<6.4 Bels @ <25° C (77° F)
To review typical system power ratings, use the Active Answers Power Calculator, which is available online at
http://h30099.www3.hp.com/configurator/powercalcs.asp
.
Table 11 Power supply requirements
Item Description
Model API4FS18+490
PSU type 1U 650 W
Input type AC