Memory
Table 5-3: SDRAM DIMM Specifications
Item Description
Size 512 MB and 1GB
Speed 266 MHz
Width 64 bits
Type PC2100 ECC registered DDR SDRAM DIMMs
Note: DIMMs must be industry-standard 184-pin PC2100 DDR DIMMs. The DDR DIMMs must
support CAS Latency 2, or greater. They must also contain the mandatory Joint Electronic Device
Engineering Council (JEDEC) Serial Presence Detect (SPD). Use HP supplied DIMMs only.
Table 5-2: Power Supply Specifications
Item Description
Input characteristics
Rated input voltage 100 VAC to 240 VAC
Rated input line 110VAC / 220 VAC
Frequency range 50 to 60 Hz
Rated input power 440 W
Rated input current 4.5 A (100 V) to 2.1 A (240 V)
Output characteristics
Steady state power 325 W
Maximum peak power 422 W for 15 seconds.
Ambient temperature range
Operating
10°C to 48°C (50°F to 118°F)
Non-operating
-40°C to 70°C (-40°F to 158°F)
Relative humidity (non-condensing)
Operating 5% to 85%
Non-operating 5% to 95%
Dielectric voltage withstand
Input to output 1800 VAC/second
Input to ground 1800 VAC/second
Maximum wet-bulb temperature
28°C (82.4°F)