HP ProLiant DL140 Server Maintenance and Service Guide
HP ProLiant DL140 Server Maintenance and Service Guide 48
System Unit
Table 5-1: System Unit Specifications
Item Description
Height 4.37 cm (1.72 in)
Depth 60.22 cm (23.7 in)
Width 43.0 cm (16.9 in)
Weight (maximum) 11.00 kg (24.2 lb)
U.S. and international input voltage requirements
Rated input voltage 100 VAC to 240 VAC
Rated input frequency 50 Hz to 60 Hz
Rated input current 4.5A (100-120 V) / 2.5A (200-240 V)
Rated input power 440 W
BTUs per hour 1509
Temperature range
1
Operating
10°C to 35°C (50°F to 93°F)
Shipping
-40°C to 60°C (-40°F to 140°F)
Relative humidity (non-condensing)
2
Operating 10% to 90%
Non-operating 10% to 95%
Maximum wet-bulb temperature
28°C (82.4°F)
1
Operating temperature has an altitude derating of 1°C per 308.4 M (1.8°F per 1000 ft). No direct
sunlight.
2
Storage maximum humidity of 95 percent based on maximum temperature of 45°C (113°F).
Altitude minimum for storage is 70 KPa.