HP ProLiant DL140 Generation 3 Server Maintenance and Service Guide
Contents 103
Gigabit Ethernet controller
Table 17 Gigabit Ethernet controller specifications
Item Description
Model Broadcom BCM5721 NetXtreme
Network interface 10/100/1000Base-T Ethernet
Media interface controller (MAC) Triple speed, IEEE 802.3 compliant
System interface Single lane 4-pin PCI-X
Connector RJ-45
Industry-compliant manageability features • IPMI 2.0 support
• Standards-compliant WOL
Package 15 x 15 mm
Power supply unit
Table 18 Power supply unit specifications
Item Description
Model Delta TDPS-650CB
PSU type 1U 650-watts
Input type AC
Input requirements
Input voltage range
Normal voltage range
Input frequency range
90 VAC to 264 VAC (wide range, single phase)
100 VAC to 240 VAC
47 Hz to 63 Hz.
Inrush current 40 A max; 60 A peak for 1 ms
Maximum input current 11A at 90 VAC; 5.5 A at 180 VAC, full load
Maximum wet-bulb temperature 29°C (84.2°F)