HP Insight Management WBEM Providers for HP integrated VMWare ESXi
System Power
Supply
Table 10-21 Class: SMX_PowerMeter
Property name Property implementation
DeviceID Unique identifier for this power utilization sensor
SystemCreationClassName SMX_ComputerSystem.CreationClassName
SystemName SMX_ComputerSystem.Name
CIM_LogicalElement
CIM_EnabledLogicalElement
EnabledDefault 2 (Enabled)
EnabledState 5 (Not Applicable)
RequestedState 12 (Not Applicable)
CIM_Sensor
SensorType 13 (Power Consumption)
CurrentState “Normal”
PossibleStates Array may contain the following value:
PossibleStates[0] = ”Normal”
CIM_NumericSensor
CurrentReading Current reading of the power meter
BaseUnits 7 (Watts)
RateUnits 0 (None)
UnitModifier 0
HP_PowerMeter
10-3-21 SMX_SystemPowerMeter
The SMX_SystemPowerMeter class associates the SMX_ComputerSystem instance with the
SMX_PowerMeter instance.
Table 10-212
Class: SMX_SystemPowerMeter
Property name Property implementation
GroupComponent References SMX_ComputerSystem
PartComponent References SMX_PowerMeter
10-3-22 SMX_AssociatedPowerMeter
The SMX_AssociatedPowerMeter class associates the SMX_PowerSupply instance with the
SMX_PowerMeter instance.