HP Insight Management WBEM Providers for HP integrated VMWare ESXi

System Power
Supply
10-3-20 SMX_PowerMeter
SMX_PowerMeter is used to model power utilization on Servers. Not all systems support reporting
power utilization information.
NOTE: Power supply numbers for existing instances do not change when other power supplies are
added and removed.
Table 10-21
Class: SMX_PowerMeter
Property name Property implementation
CIM_ManagedElement
Caption Short description of this power utilization sensor using
the name of the power supply displayed by the MP or
iLO and location.
For example: Power utilization sensor for Power
Supply 1 at PowerSupplySlot=1
Description Description of this power utilization sensor including
the Caption and StatusDescriptions.
For example: Power utilization sensor for Power Supply
1 at PowerSupplySlot=1. StatusDescription
where StatusDescription represents the value of
StatusDescriptions[0]
ElementName Short description of this power utilization sensor using
the name of the power supply displayed by the MP or
iLO.
For example: Power utilization sensor for Power
Supply 1
CIM_Managed SystemElement
OperationalStatus[0] 2 (OK) – if power utilization sensor is operating
properly
StatusDescriptions[0] Description of the status of the power utilization sensor
corresponding to the OperationalStatus.
For example:Power Supply is operating properly – if
OperationalStatus[0] is 2 (OK);
HealthState 5 (OK) – if power utilization sensor is operating
properly
Name Short description of this power utilization sensor using
the name of the power supply displayed by the MP or
iLO and location.
For example: Power utilization sensor for Power
Supply 1 at PowerSupplySlot=1
CIM_LogicalDevice
CreationClassName “SMX_PowerMeter”