HP Insight Management WBEM Providers for HP integrated VMWare ESXi
Smart Array
4-4-22 HP_DeviceIndication: Enclosure Fan status
changed to OK
Table 4-116
HP_DeviceIndication: Enclosure Fan status changed to OK
Property name Property implementation
RecommendedActions No action required
SystemName Name of the computer system generating the indication
SystemCreationClassName CreationClassName of the computer system generating
the indication
HP_AlertIndication
Summary Fan Status OK
EventCategory 24 (Primary Storage Cooling)
ProbableCause 1 (Other)
ProbableCauseDescription Fan Status Changed to OK
NetworkAddresses Contains a list of all the IP addresses of the computer
system generating the indication
OSType SMX_OperatingSystem.OSType
OSVersion Operating system version of the computer system
generating the indication in the format,
<major>.<minor>.<build>
ProviderVersion 2.2.0.0
SystemFirmwareVersion Firmware version of the computer system generating
the indication
SystemSerialNumber Serial number of the computer system generating the
indication
SystemProductID Product ID of the computer system generating the
indication
SystemModel Model name of the computer system generating the
indication
SystemGUID Platform GUID of the computer system generating the
indication
ImpactedDomain 3 (Enclosure) for c-Class blade systems
4 (System) for all other systems
When ImpactedDomain is 3 (Enclosure), the properties
indicated with (*) are populated.
BladeBay * HP_BladeCSLocation.LocationInformation[0]
BladeName * HP_ComputerSystem.Name
EnclosureName * HP_BladeEnclosureCS.Name