Technologies in HP ProLiant G7 c-Class server blades with AMD Opteron™ processors, 3rd Edition

12
When connected to a converged enhanced Ethernet (CEE) capable switch, Fibre Channel and Ethernet I/O are
separated and routed to the corresponding network.
For iSCSI storage, the NC551i LOM supports full protocol offload that provides better CPU efficiency when
compared to software initiators. Because of this, the server can handle increased virtualization workloads and
compute-intensive applications. Accelerated iSCSI offloads the iSCSI function from the server CPU to the NIC. You
can use the HP ProLiant Essentials Accelerated iSCSI Pack with certain multi-function NICs in Windows and Linux
environments. To see the supported servers, NICs, and operating systems, go to the QuickSpecs at
The NC551i LOM also supports Virtual Connect Flex-10 that allows dividing each 10 Gb port into four physical
NICs to optimize bandwidth management. This combination of high-performance network and storage connectivity
reduces cost and complexity. It provides the flexibility and scalability to optimize the data center.
http://h18002.www1.hp.com/products/servers/proliantessentials/aip/index.html.
Virtual Connect
HP Virtual Connect (VC) is a portfolio of interconnect modules and embedded software for c-Class enclosures. VC
management capability includes control of networks, SAN fabrics, server profiles, and user accounts that make it
simpler to set up and manage server connections. VC implements server-edge virtualization so that you can
upgrade, replace, or move server blades within their enclosures without visible changes to the external LAN and
SAN environments.
VC Flex-10 technology helps administrators fully use 10 GbE connection bandwidth. Using Flex-10, you can
partition the bandwidth of a single 10 Gb pipeline into multiple FlexNICs. You can also regulate the bandwidth for
each from 100 Mb/s to 10 Gb/s in 100 Mb increments.
HP VC FlexFabric extends VC Flex-10 technology to include FCoE and iSCSI converged storage traffic. The result is
a CEE-based FCoE network with Flex-10 variable bandwidth and 10 Gb partitioning abilities that can handle
Ethernet, iSCSI, and Fibre Channel traffic. This means that you can connect BladeSystem servers to network and
storage infrastructure with a single server connection and a single VC interconnect module. You can connect not
only to Fibre Channel SANs but also to iSCSI storage via accelerated iSCSI technology (hardware initiated iSCSI)
over a Flex-10 connection. A single pair of VC modules will aggregate an entire enclosure‘s traffic and connect to
existing 1 Gb or 10 GbE and native Fibre Channel external networks.
Full details about VC technology are available in the technology brief titled “HP Virtual Connect technology
implementation for the HP BladeSystem c-Class” at
Data security technology with the Trusted Platform Module
http://h20000.www2.hp.com/bc/docs/support/SupportManual/c00814156/c00814156.pdf.
The Trusted Platform Module (TPM) is a hardware-based system that can securely store information such as
passwords and encryption keys to authenticate the platform. You can also use TPM to store platform measurements
that help ensure that the platform remains trustworthy. HP ProLiant G7 AMD-based server blades support an
optional TPM v1.2. A rivet supplied with the optional TPM v1.2 module attaches and secures the module to the TPM
riser board. To prevent possible damage to the TPM module or to the TPM riser board, you cannot remove the TPM
from the board once you have installed it.
For additional information about the TPM, see the HP paper titled “Data security in HP ProLiant servers using the
Trusted Platform Module and Microsoft® Windows® BitLocker™ Drive Encryption” at
http://h20000.www2.hp.com/bc/docs/support/SupportManual/c01681891/c01681891.pdf.