HP ProLiant BL685c G7 Server Blade Maintenance and Service Guide
Removal and replacement procedures 44
IMPORTANT: Heatsinks for processors 1 and 2 are not interchangeable with the heatsinks for
processors 3 and 4.
9. Install the heatsink ("Heatsink" on page 32).
IMPORTANT: Install all components with the same configuration that was used on the failed
system board.
10. Install all components removed from the failed system board assembly.
11. Install the front panel/hard drive cage assembly ("Front panel/hard drive cage assembly" on page
30).
12. Install the hard drives ("Hard drive" on page 25).
IMPORTANT: To avoid damage to the server blade, support the riser board when installing the
TPM board and rivet.
13. If necessary, install the TPM module. For more information, see the HP ProLiant BL685c G7 Server Blade
User Guide.
14. Install the access panel ("Access panel" on page 24).
After you replace the system board, you must re-enter the server blade serial number and the product ID.
1. During the server blade startup sequence, press the F9 key to access RBSU.
2. Select the Advanced Options menu.
3. Select Service Options.
4. Select Serial Number. The following warnings appear:
WARNING! WARNING! WARNING! The serial number is loaded into the system during
the manufacturing process and should NOT be modified. This option should only
be used by qualified service personnel. This value should always match the
serial number sticker located on the chassis.
Warning: The serial number should ONLY be modified by qualified personnel.
This value should always match the serial number located on the chassis.
5. Press the Enter key to clear the warning.
6. Enter the serial number and press the Enter key.
7. Select Product ID. The following warning appears: