HP ProLiant BL685c Generation 5 Server Maintenance and Service Guide

Removal and replacement procedures 26
DIMM baffle
CAUTION: To avoid damage to the server blade and the enclosure, install all DIMM baffles in
the proper location after adding or replacing DIMMs. DIMM baffles that are missing or installed
incorrectly can compromise server blade and enclosure cooling.
To remove the component:
1. Power down the server blade (on page 22).
2. Remove the server blade (on page 23).
3. Remove the access panel ("Access panel" on page 24).
4. Remove the DIMM baffle.
CAUTION: To avoid damage to the server blade and the enclosure, install all DIMM baffles in
the proper location after adding or replacing DIMMs. DIMM baffles that are missing or installed
incorrectly can compromise server blade and enclosure cooling.
DIMM baffles for processor 1 and 2 memory banks have a single top gasket. DIMM baffles for processors 3
and 4 memory banks have a top and a side gasket.
To replace the component:
1. Install the DIMM baffles:
o Install DIMM baffles for processor 1 and 3 memory banks with the R toward the front of the server
blade.
o Install DIMM baffles for processor 2 and 4 memory banks with the L toward the front of the server
blade.
2. Install the access panel ("Access panel" on page 24).
3. Install the server blade.
DIMMs