HP ProLiant BL465c Gen8 Server Blade Maintenance and Service Guide

Removal and replacement procedures 55
10. Install the heatsink ("Heatsink" on page 42).
IMPORTANT: Install all components with the same configuration that was used on the failed
system board.
11. Install all components removed from the failed system board.
12. Install the front panel/hard drive cage assembly ("Front panel/drive cage assembly" on page 39).
13. Install all drives ("Drive" on page 25).
IMPORTANT: To avoid damage to the server blade, support the riser board when installing the
TPM board and rivet.
14. If necessary, install the TPM module. For more information, see the HP ProLiant BL465c Gen8 Server
Blade User Guide.
15. Install the access panel ("Access panel" on page 24).
After you replace the system board, you must re-enter the server blade serial number and the product ID.
1. During the server blade startup sequence, press the F9 key to access RBSU.
2. Select the Advanced Options menu.
3. Select Service Options.
4. Select Serial Number. The following warning appears:
Warning: The serial number should ONLY be modified by qualified service
personnel. This value should always match the serial number located on the
chassis.
5. Press the Enter key to clear the warning.
6. Enter the serial number and press the Enter key.
7. Select Product ID. The following warning appears:
Warning: The Product ID should ONLY be modified by qualified service
personnel. This value should always match the Product ID located on the
chassis.
8. Enter the product ID and press the Enter key.
9. Press the Esc key to close the menu.
10. Press the Esc key to exit RBSU.