HP ProLiant BL465c Gen8 Server Blade Maintenance and Service Guide
Removal and replacement procedures 36
6.
Remove the NAND flash module from the Smart Array P220i Controller.
To replace the component, reverse the removal procedure.
FBWC procedures
Three types of procedures are provided for the FBWC option:
• Removing the SAS controller capacitor pack (on page 36)
• Removing the mezzanine option capacitor pack (on page 37)
• Recovering data from the FBWC (on page 38)
Removing the SAS controller capacitor pack
To remove the component:
1. Power down the server blade (on page 22).
2. Remove the server blade (on page 23).
3. Remove the access panel ("Access panel" on page 24).
4. Disconnect the capacitor pack cable from the SAS controller.
5. Disconnect the drive cables from the SAS controller and remove the DIMM baffle ("DIMM baffle" on
page 27).