HP ProLiant BL465c Gen8 Server Blade Maintenance and Service Guide
Removal and replacement procedures 35
To replace the component:
1. Install the SAS controller.
2. Install the DIMM baffle and connect the drive cable to the SAS controller ("DIMM baffle" on page 27).
3. Install the access panel ("Access panel" on page 24).
NAND flash module for the Smart Array P220i
Controller
To remove the component:
1. Power down the server blade (on page 22).
2. Remove the server blade (on page 23).
3. Remove the access panel ("Access panel" on page 24).
CAUTION: Always disconnect the drive cables from the SAS controller before removing the
DIMM baffle. Failure to do so may result in damage to the SAS controller.
4. Disconnect the drive cables from the SAS controller and remove the DIMM baffle ("DIMM baffle" on
page 27).
5. Remove the SAS controller ("SAS controller" on page 34).