HP ProLiant BL465c Generation 5 Server Blade Installation Instructions

Interconnect bay numbering and device
mapping
To support network connections for specific signals, install an
interconnect module in the bay corresponding to the
embedded NIC or mezzanine signals.
Server blade
signal
Interconnect bay Interconnect bay labels
NIC 1
(Embedded)
1
NIC 2
(Embedded)
2
Mezzanine 1 3 and 4
Mezzanine 2 5 and 6
7 and 8
For detailed port mapping information, see the HP
BladeSystem enclosure installation poster or the
HP BladeSystem enclosure setup and installation guide on the
HP website
(http://www.hp.com/go/bladesystem/documentation
).
Connecting to the network
To connect the HP BladeSystem to a network, each enclosure
must be configured with network interconnect devices to
manage signals between the server blades and the external
network.
Two types of interconnect modules are available for HP
BladeSystem c-Class enclosures: Pass-thru modules and switch
modules. For more information about interconnect module
options, see the HP website
(http://www.hp.com/go/bladesystem/interconnects
).Installin
g a server blade
CAUTION: To prevent improper coolin
g
and thermal
damage, do not operate the server blade or the
enclosure unless all hard drive and device bays are
populated with either a component or a blank.
1. Remove the blank.
2. Remove the enclosure connector cover.
3. Prepare the server blade for installation.